Publisher: Mumbai Indian Drug Manufacture's Association - IDMA 2018Edition: Vol. 55 (03) March.Description: 58-61.Subject(s): PHARMACEUTICS | ICH guidelines, and validationOnline resources: Click here In: Indian drugsSummary: Three-wavelength spectrophotometric method has been developed for the simultaneous estimation of atazanavir sulfate (ATZ) and ritonavir (RIT) in pharmaceutical preparations. The absorbance value at 279.7nm was used for the estimation of ATZ where RIT showed zero absorbance. The absorbance value for RIT was estimated by taking difference in absorbance at two wavelengths 248 nm and 252 nm. This method obeyed Beer’s law in the concentration range of 9-45 μg/mL for ATZ, and 3-15 µg/mL for RIT. The results of analysis have been validated statistically and recovery studies confirmed the accuracy of the proposed method. The percentage recoveries were found to be 101.3±0.4 for ATZ and 99.8± 0.2 for RIT. The assay values of atazanavir and ritonavir were found to be 100.7±0.7 and 103.0±1.2, respectively. The method was found to be simple, rapid, accurate, precise and sensitive. Hence, this method can be used for routine analysis of these drugs in formulations.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2018057
Total holds: 0

Three-wavelength spectrophotometric method has been developed for the simultaneous estimation of atazanavir sulfate (ATZ) and ritonavir (RIT) in pharmaceutical preparations. The absorbance value at 279.7nm was used for the estimation of ATZ where RIT showed zero absorbance. The absorbance value for RIT was estimated by taking difference in absorbance at two wavelengths 248 nm and 252 nm. This method obeyed Beer’s law in the concentration range of 9-45 μg/mL for ATZ, and 3-15 µg/mL for RIT. The results of analysis have been validated statistically and recovery studies confirmed the accuracy of the proposed method. The percentage recoveries were found to be 101.3±0.4 for ATZ and 99.8± 0.2 for RIT. The assay values of atazanavir and ritonavir were found to be 100.7±0.7 and 103.0±1.2, respectively. The method was found to be simple, rapid, accurate, precise and sensitive. Hence, this method can be used for routine analysis of these drugs in formulations.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha